In order to ensure the stability and high efficiency of the labeling machine operation, in addition to the extra effort in the daily operation, it is very important for the user to understand and master the necessary maintenance methods of the equipment. A labeling machine, others have high labeling efficiency and long service life, and their labeling machine has low efficiency and long service life. The reason for this is not only the operation method, but also the maintenance and maintenance. Next, Xiaobian will introduce the maintenance and adjustment methods of each component of the labeling machine. I hope that the following introduction can help you use the labeling machine.
1. Adjustment of the label box: the center line of the label box, the central axis of the label station is tangent to the label paper, and the center axis of the label board is lined up at three points, adjusted to the label (tang distance) and the label paper (0 distance), and then the label box is moved. It can be nearly 1mm~2mm. The gap between the standard paper and the bead on both sides should be between 0.8mm-1mm. The gap is too large, causing the standard paper to shift in the standard box, and the oblique mark appears; if the gap is too small, the push mark will be poor. The adjustment of the position of the labeling hook of the standard box: the upper and lower and the left and right grasping hooks are on the same vertical plane and evenly work on the standard paper, so that the label can be smoothly captured. Adjustment of the label supply roller: When there is no label, the label platen can be pressed to the front end of the label box and the label near the label hook finger cannot be crushed.
2. Adjustment of the brushing device: the center of the brush is aligned with the label and symmetric on both sides, and perpendicular to the surface of the container. The overlapping gap of the brushing sweeping container is: a single pressing brush is 10 mm to 15 mm, and the combined pressing brush is 5 mm to 10 mm. The position of the cleaning brush from the sponge is 1 mm to 2 mm. The bottle head should be 20mm lower than the bottle when there is no bottle.
3. Adjustment of the standard station: adjustment of the squeegee and the rubber roller: the squeegee and the rubber roller should not have a gap in the whole length. If there is a gap, the squeegee can be adjusted by adjusting the eccentric bolt. Adjustment of the rubber roller and the target plate: the target plate and the rubber roller only contact each other without any pressure. If the gap is too large, there will be too much glue on the target board, causing the glue; the gap is too small, the contact is too tight, the glue will be squeezed away, and there is no glue on the half of the target. Practice has proved that the gap between the target plate and the rubber roller is between 0.1mm and 0.2mm, which can be achieved by adjusting the bearing seat at the lower part of the rubber roller. If necessary, adjust the bearing on the upper part of the rubber roller.
4. Adjustment of the bottle star wheel, the bottle star wheel and the bottle screw: When adjusting the inlet and outlet star wheel and the feeding screw, the pressure bottle head of the standard machine shall prevail. Adjustment of the bottle into the star wheel: When the bottle head just overwhelm the bottle, adjust the bottle into the star wheel so that the bottle is in the middle of the groove of the star wheel. Adjustment of the inlet screw: According to the inlet star wheel, when the bottle is in the middle of the groove of the inlet star wheel, adjust the auger so that the auger is pressed against the bottle side without displacement. Adjustment of the bottle star wheel: When the bottle head has just been lifted, adjust the star wheel so that the bottle is in the middle of the groove of the star wheel.
In addition, in terms of maintenance, we also need to focus on the following points:
1. When the labeling machine is temporarily idle, you should unplug the power supply and cover it with a dust-proof cloth to avoid dust on the labeling machine. In addition, the high temperature belt of the labeling machine also needs to be regularly cleaned and decontaminated in order to make the labeling machine work better.
2. The labeling machine should be applied with lubricating oil after a period of use. Because many parts of the labeling machine, such as gears, bearings and gearboxes, are prone to rust and wear after use. The lubricant is applied and the parts are smoother.
3. The working environment of the labeling machine should be kept ventilated and dry. The room temperature of the good environment is 25 degrees Celsius.
4. If you want to keep the labeling machine working for a long time, you need to check the operation of the cooling fan to ensure that the temperature is not too high, so as not to burn the electrical system.
5. In the daily use process, the labeling machine needs to be cleaned and maintained regularly, because the equipment is relatively easy to cause dust deposition, so it should be cleaned every once in a while.
6. In order to ensure the smooth operation and normal use of the labeling machine, it is necessary to clean the high temperature parts regularly, especially the coding machine.
Like countless mechanical equipment, the use of labeling machines is inseparable from the daily correct use and maintenance, only the two at the same time, in order to ensure that the labeling machine to play a strong performance.

Fitness Equipment

Fitness Equipment,Folding Fitness Equipment,Fitness Mini Gym Equipment,Home Fitness Equipment

Haloxylon Ammodendron Medical Equipment Co., Ltd. , https://www.ssmedicaldevic.com