Targeted ribonuclease ( TR ) ELISA test kit instruction manual
This reagent is for research use only. Specimen: serum or plasma
Ancient flower supply
Purpose of use: This kit is used to determine the ribonuclease (TR) content of serum, plasma and related liquid samples.
Test principle:
The TR kit is a solid phase sandwich enzyme-linked immunosorbent assay (ELISA). Standards of known TR concentrations and samples of unknown concentration are added to the microplates for detection. TR and biotinylated antibodies were first incubated simultaneously. After washing, avidin-labeled HRP was added. After incubation and washing, the unbound enzyme conjugate is removed, then the substrates A, B, and the enzyme conjugate are added simultaneously. Produce color. The depth of the color is proportional to the concentration of TR in the sample.
The performance of kit:
1 sensitivity: minimum detection concentration is less than 1 standard. LiTRarity of dilution. Sample liTRar regression and the expected concentration correlation coefficient R value is 0.990.
2: no specific reaction with other cytokiTRs.
3 repeaTRility: plate, plate between the coefficients of variation were less than 10%.
Targeted ribonuclease kit, elisa kit instructions, ELISA kit, ELISA kit, elisa kit instructions
Kit content and its preparation
Kit components (2-8 ° C) | 96-well configuration | 48 hole configuration | Formulation |
96/48 ELISA plate | 1 board (96T) | Half board (48T) | Ready-to-use |
Plastic diaphragm cover | 1 block | Half block | Ready-to-use |
Standard: 80ng/ml | 1 bottle (0.6ml) | 1 bottle (0.3ml) | According to the instructions for thinning |
Blank control | 1 bottle (1.0ml) | 1 bottle (0.5ml) | Ready-to-use |
Standard dilution buffer | 1 bottle (5ml) | 1 bottle (2.5ml) | Ready-to-use |
Biotinylated anti-TR antibody | 1 bottle (6ml) | 1 bottle (3.0ml) | Ready-to-use |
Affinity chain enzyme-HRP | 1 bottle (10ml) | 1 bottle (5.0ml) | Ready-to-use |
Washing buffer | 1 bottle (20ml) | 1 bottle (10ml) | Dilute according to the instructions |
Substrate A | 1 bottle (6.0ml) | 1 bottle (3.0ml) | Ready-to-use |
Substrate B | 1 bottle (6.0ml) | 1 bottle (3.0ml) | Ready-to-use |
Stop solution | 1 bottle (6.0ml) | 1 bottle (3.0ml) | Ready-to-use |
Specimen dilution | 1 bottle (12ml) | 1 bottle (6.0ml) | Ready-to-use |
Self-contained materials
1. Distilled water.
2. Sampler: 5ul, 10ul, 50ul, 100ul, 200ul, 500ul, 1000ul.
3. Oscillators and magnetic stirrers, etc.
safety
1. Avoid direct contact with the stop solution and substrates A, B. Once exposed to these liquids, rinse with water as soon as possible.
2. Do not eat, drink, smoke or use cosmetics during the experiment.
3. Do not use your mouth to take any ingredients from the kit.
Operational precautions
1. Reagents should be stored according to the label instructions and returned to room temperature before use. Standards after dilution should be discarded and cannot be stored.
2. The slats not used in the experiment should be immediately put back into the bag and sealed to prevent deterioration.
3. Other reagents not used should be packaged or covered. Do not mix reagents of different batches. Use before warranty.
4. Use a disposable tip to avoid cross-contamination. Avoid pipettes with metal parts when drawing stop solution and substrate A and B.
5. Use a clean plastic container to configure the wash solution. Mix all the ingredients and samples in the kit thoroughly before use.
6. Wash the enzyme plate should be fully patted dry, do not put the absorbent paper directly into the enzyme standard reaction well to absorb water.
7. Substrate A should be volatilized to avoid opening the lid for extended periods of time. Substrate B is sensitive to light and avoids prolonged exposure to light. Avoid contact with hands and be toxic. The OD value should be read immediately after the experiment is completed.
8. The order of addition of reagents should be consistent to ensure that all wells are incubated for the same time.
9. The incubation was carried out according to the time indicated in the instructions, the amount of addition and the order.
Sample collection, processing and storage methods
1. Serum ---- Avoid any cell irritation during the procedure. Use tubes without pyrogens and endotoxins. After collecting the blood, the serum and red blood cells were quickly and carefully separated by centrifugation at 1000 x g for 10 minutes.
2, plasma ----- EDTA, citrate, heparin plasma can be used for testing. The pellet was removed by centrifugation at 1000 x g for 30 minutes.
3. Cell supernatant - 1000 x g was centrifuged for 10 minutes to remove particles and polymer.
4, tissue homogenate ----- the tissue is added to the appropriate amount of physiological saline mash. Centrifuge at 1000 × g for 10 minutes, take the supernatant
5. Storage ------If the sample is not used immediately, it should be divided into small parts - 70 °C to avoid repeated freezing. Do not use hemolysis or hyperlipemia as much as possible. If there are large amounts of particles in the serum, centrifuge or filter before testing. Do not heat thaw at 37 ° C or higher. It should be thawed at room temperature and ensure that the sample is fully thawed evenly.
2. Dilution of wash buffer (50 x): 50-fold dilution of distilled water.
Steps
1. Mix all reagents thoroughly before use. Do not allow the liquid to generate a large amount of foam, so as to avoid adding a large amount of air bubbles during the loading, resulting in errors in the loading.
2. The number of slats required is determined by the number of samples to be tested plus the number of standards. Multiple holes are recommended for each standard and blank hole. Each sample is determined according to its own quantity, and it is possible to use the double hole as much as possible to make a double hole. The specimen was diluted 1:1 with the specimen dilution and 50 ul was added to the reaction well.
3. 50 ul of the diluted standard was added to the reaction well, and 50 ul of the sample to be tested was added to the reaction well. Immediately add 50 ul of biotinylated antibody. Cover the membrane, mix gently by shaking, and incubate for 1 hour at 37 °C.
4. Remove the liquid from the well, fill each well with the washing solution, shake for 30 seconds, remove the washing solution, and pat dry with absorbent paper. Repeat this operation 3 times. If washing with a washer, the number of washings is increased once.
5. 80 ul of affinity streptavidin-HRP was added to each well, and the mixture was gently shaken and incubated at 37 ° C for 30 minutes.
6. Remove the liquid from the well, fill each well with the washing solution, shake for 30 seconds, remove the washing solution, and pat dry with absorbent paper. Repeat this operation 3 times. If washing with a washer, the number of washings is increased once.
7. Add 50 μl of each of the substrates A and B to each well, mix gently by shaking, and incubate at 37 ° C for 10 minutes. Avoid lighting.
8. Remove the microplate and quickly add 50 ul of stop solution. Immediately after adding the stop solution, the results should be determined.
9. The OD value of each well was measured at a wavelength of 450 nm.
Limit
The results above the No. 6 standard are non-linear and no accurate results can be obtained from this standard curve.
Targeted ribonuclease ( TR ) ELISA kit performance
1. Sensitivity: The minimum detection concentration is less than the No. 1 standard. The linearity of the dilution. The linear regression coefficient of the sample and the expected concentration correlation coefficient R value was 0.990.
2. Specificity: Does not react with other cytokines.
3. Repeatability: The coefficient of variation between the plate and the plate is less than 10%.
Result judgment and analysis
1. Instrument value: read the OD value of each hole on a microplate reader with a wavelength of 450 nm.
2. The absorbance OD value is the ordinate (Y), and the corresponding TR standard concentration is the abscissa (X), and the corresponding curve is obtained. The TR content of the sample can be converted into the corresponding concentration according to the OD value from the standard curve.
3. Detection range: 0-80ng/ml
4. Sensitivity: 0.1 ng/ml
1-Piece Ostomy pouch MDK-BO-01 300ML
A one-piece colostomy bags, drainable pouching system designed to be opened at the bottom when emptying. These colostomy bag machine are most suitable for colostomies or ileostomies. Ostomy bag colostomy barrier is a standard wear skin barrier that is gentle to the skin and allows for frequent pouch removal. To close the pouch, use the curved, beige clamp. Soft, beige disposable colostomy bag pouch panels on body side help provide comfort.
The features are soft and flex,standard wear, skin barrier, flat. The Chassis made in 100% hydrocolloid No tape border. Cut-to-fit skin barrier. Ultra-clear odor-barrier pouch film. Curved, beige pouch clamp. With comfortable ware pouch panel body side only. Not made with natural rubber latex.
Ostomy urostomy colostomy bag care products consist of sodium carboxymethylcellulose, adhesives made from medical hot melt adhesives, and separator paper or separators. Nursing equipment for ileum, colon, rectum or urethral stoma,The coloplast colostomy bag comes into contact with intact skin and intestinal lumen,Non-sterile supply. Colostomy bag reusable for stoma washing, care and collection of excreta and skin care around the stoma.
Use disposable colostomy bag, make sure the skin around the stoma is clean and dry before use. Remove the bags for colostomi from the package and separator or paper. Reshape the coloplast colostomy bag into the desired shape and size to fit the skin around the stoma. Apply the colostomy convatec bag to the skin around the stoma,adjust the shape of the paste again,Gently press so that it is firmly flat on the skin. Attach the stoma colostomy bag undercarriage to the stoma. The colostomy bag care can be peeled off the skin, don`t reuse. These one-piece-colostomy bag or two-piece-colostomy-bag are non-sterile product and is valid for three years under the condition of meeting the storage conditions.
2-Piece Ostomy Pouch,2 Piece Ostomy Bags,2 Piece Stoma Bags,Two Piece Stoma Bag
Henan Maidingkang Medical Technology Co.,Ltd , https://www.mdkmedicales.com